| FREQ |
FREQUENCY IN HERTZ |
60.0 |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
WATERTIGHT AND DRIPPROOF |
| AQZF |
CONTROL TYPE |
LOCAL OR REMOTE |
| ABHP |
OVERALL LENGTH |
19.380 INCHES NOMINAL |
| ANRH |
AMP SIZE RATING |
18.0 |
| ACYN |
AC VOLTAGE RATING |
440.0 VOLTS NOMINAL |
| FEAT |
SPECIAL FEATURES |
CONTRACT NO.N00024-98-C-2104MODP00031;THERE ARE APPROVED EXCEPTIONS TO MIL-C-2212 CONCERNING OVERLOAD RELAY AMPERAGE-SEE DRAWING 6962ED3688;SHOCKPROOF GRADE A CLASS 1 OF MIL-S-901 |
| ANDX |
AMBIENT TEMP |
50.0 DEG CELSIUS |
| AJXE |
SIZE DESIGNATOR |
1 |
| FAAZ |
PHASE |
THREE |
| ANDE |
ACTUATOR VOLTAGE |
440.0 AC |
| AGAV |
END ITEM IDENTIFICATION |
JP-5 FUELING/DEFUELING PUMP,SPRAYTIGHT MOTOR;CVN77 |
| ALGC |
MOUNTING CONFIGURATION |
FOUR 0.656DIA HOLES FOR 0.625DIA MOUNTING BOLTS |
| AKVZ |
ACCESSORY IDENTIFYING NUMBER |
6962ED3688 DRAWING NO. |
| AGUE |
FUSE ACCOMMODATION QUANTITY |
6 |
| ANRK |
SWITCH FUNCTIONAL POSITIONS |
RESET AND START AND STOP AND EMERGENCY RUN |
| ANQC |
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN |
DESIGNED PER NEMA STD |
| ANCY |
HORSEPOWER RATING |
5.000 AND 10.000 |
| ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL |
| ABKW |
OVERALL HEIGHT |
29.120 INCHES NOMINAL |
| AKPS |
DUTY CYCLE |
CONTINUOUS |
| AFLW |
ACTUATION METHOD |
MAGNETIC |
| AKVY |
ACCESSORY CONTROLLING AGENCY |
NAVICP-M/DRS |
| ANPZ |
INCLOSURE FEATURE |
WATERTIGHT AND DRIPPROOF |
| ABMK |
OVERALL WIDTH |
8.700 INCHES NOMINAL |
| ANDW |
LOAD PROTECTION TYPE |
OVERLOAD AND UNDERVOLTAGE |
| ANCN |
OPERATING VOLTAGE CHARACTERISTIC |
FULL |
| ANDG |
FUSE CURRENT RATING IN AMPS |
5.0 AND 10.0 |
| CBBL |
FEATURES PROVIDED |
ACCESSORY LOCATION EXTERNAL AND CIRCUIT PROTECTION FUSE |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
CONTROLLER A.C. MAGNETIC SIZE 1 |