| ACUT |
DIRECT CURRENT RATING IN AMPS |
14.3 |
| AENK |
COOLING METHOD |
RADIATOR |
| ABHP |
OVERALL LENGTH |
44.000 INCHES NOMINAL |
| AYHE |
EXCITOR TYPE |
SELF-EXCITED |
| AYSA |
CRANKING VOLTAGE IN VOLTS |
28.0 |
| ACDC |
CURRENT TYPE |
AC OR DC |
| AZBN |
PRIME MOVER MANUFACTURER NAME |
HERCULES MOTOR CORP |
| AMWJ |
WINTERIZATION FEATURE |
NOT INCLUDED |
| AZCB |
HOUSING TYPE |
OPEN |
| AYQZ |
PRIME MOVER STARTING METHOD |
MANUALLY BY CRANK |
| AQGA |
MANUFACTURER NAME |
HOMELITE CORP |
| AZBP |
PRIME MOVER IDENTIFYING NUMBER |
MODEL NO. ZXB |
| AYHB |
LINE TO LINE VOLTAGE IN VOLTS |
115.0 |
| FAAZ |
PHASE |
THREE |
| AAXX |
MOUNTING TYPE |
SKID |
| ABKW |
OVERALL HEIGHT |
30.000 INCHES NOMINAL |
| ACZB |
FREQUENCY RATING |
400.0 HERTZ NOMINAL |
| AZCM |
TEMP RISE RATING IN DEG CELSIUS FOR CONTINUOUS OPERATION |
NOT RATED |
| ABMK |
OVERALL WIDTH |
22.000 INCHES NOMINAL |
| AKSJ |
ITEM NAME ASSIGNED BY GOVERNMENT AGENCY |
POWER UNIT |
| AGAV |
END ITEM IDENTIFICATION |
TYPE NO. AN/TPS-1B |
| AZCL |
AMBIENT TEMP IN DEG CELSIUS |
40.0 |
| ACYR |
DC VOLTAGE RATING |
28.0 VOLTS NOMINAL |
| AZBM |
AUTOMATIC STARTING FEATURE |
NOT PROVIDED |
| AZKT |
RADIO INTERFERENCE SUPPRESSION |
NOT INCLUDED |
| AMSB |
IDENTIFYING NUMBER |
13A120D28-1 MODEL NO. |
| AYGY |
AC WATTAGE RATING |
4.0 KILOWATTS AND 4.5 KILOWATTS |
| AAXS |
PRIME MOVER COOLING MEDIUM |
LIQUID |
| AYHD |
POWER FACTOR IN PERCENT |
0.9 |
| AYHC |
LINE TO NEUTRAL VOLTAGE IN VOLTS |
115.0 |