| AFHS |
ACCESSORY COMPONENT QUANTITY |
1 AND 1 |
| AYHD |
POWER FACTOR IN PERCENT |
80.0 |
| AZBS |
TURBINE TO GENERATOR COUPLING METHOD |
REDUCTION GEAR |
| ABKW |
OVERALL HEIGHT |
177.750 INCHES NOMINAL |
| ABHP |
OVERALL LENGTH |
242.063 INCHES NOMINAL |
| AMSB |
IDENTIFYING NUMBER |
920J412 DRAWING NO. |
| AKVZ |
ACCESSORY IDENTIFYING NUMBER |
432-D-068 DRAWING NO. AND 906-J-119 DRAWING NO. |
| AZBR |
EXHAUST TYPE |
CONDENSING |
| AYGY |
AC WATTAGE RATING |
2500.0 KILOWATTS |
| AYHE |
EXCITOR TYPE |
SEPARATELY EXCITED |
| ABMK |
OVERALL WIDTH |
94.000 INCHES NOMINAL |
| AKVY |
ACCESSORY CONTROLLING AGENCY |
WESTINGHOUSE ELECTRIC CORP; WESTINGHOUSE ELECTRIC CORP |
| AAYL |
STEAM OPERATING PRESSURE |
570.0 POUNDS PER SQUARE INCH GAGE |
| AYHF |
EXCITOR |
INCLUDED |
| AWNT |
STAGE TYPE |
MULTIPLE |
| AQGA |
MANUFACTURER NAME |
WESTINGHOUSE ELECTRIC CORP |
| FAAZ |
PHASE |
THREE |
| AZCM |
TEMP RISE RATING IN DEG CELSIUS FOR CONTINUOUS OPERATION |
NOT RATED |
| ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL |
| AYHB |
LINE TO LINE VOLTAGE IN VOLTS |
450.0 |
| AZCL |
AMBIENT TEMP IN DEG CELSIUS |
50.0 |
| AZBP |
PRIME MOVER IDENTIFYING NUMBER |
906F706 DRAWING NO. |
| AAXX |
MOUNTING TYPE |
BASE |
| AZBQ |
TURBINE DESIGN TYPE |
IMPULSE |
| AZCG |
ACCESSORY COMPONENT NAME |
CONDENSER; REGULATOR,VOLTAGE |
| ACDC |
CURRENT TYPE |
AC |
| AJAA |
STEAM TEMP RATING |
850.0 DEG FAHRENHEIT |
| ZZZY |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS |
AZCL |
| AZBN |
PRIME MOVER MANUFACTURER NAME |
WESTINGHOUSE ELECTRIC CORP |