6120-01-520-8646 ( 1794-PS3 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 6120-01-520-8646 | 6120 | 015208646 | POWER SUPPLY | 0074 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CWGH | OUTPUT CURRENT RATING | 3.0 DC AMPERES MAXIMUM SINGLE POWER OUTPUT |
| ABMK | OVERALL WIDTH | 3.400 INCHES NOMINAL |
| AMQY | INSTALLATION DESIGN | PANEL AND WALL |
| ABHP | OVERALL LENGTH | 3.700 INCHES NOMINAL |
| APPA | OUTPUT VOLTAGE RATING | 20.4 DC VOLTS MINIMUM SINGLE POWER OUTPUT AND 27.6 DC VOLTS MAXIMUM SINGLE POWER OUTPUT |
| ABKW | OVERALL HEIGHT | 2.700 INCHES NOMINAL |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 SINGLE POWER OUTPUT |
| AYNH | OPERATING AMBIENT TEMP RANGE | +0.1/+50.0 DEG CELSIUS |
| APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| CWHM | INPUT CURRENT RATING | 1.9 AC AMPERES MAXIMUM SINGLE OPERATING POWER RQMT |
| APNX | INPUT VOLTAGE RATING | 120.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 230.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
| ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
| BGQR | OUTPUT WATTAGE RATING | 72.0 WATTS NOMINAL SINGLE POWER OUTPUT |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 1794-PS3 | 01121 | A | 2 | 3 | 4 | 9Z |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 1794-PS3 | 01121 | ROCKWELL AUTOMATION INC. | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | 0 | X | A | 1 | 05/28/2 | A | N | 8504900020 | 0074 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DS | N | I | |||
| DN | 9B----- | N | |||
| DF | N | SF9---N | F |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | N | 0 | X | A |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DS | SMS | Z | 1 | EA | 0 | U | D | ||
| DF | SMS | Z | 1 | EA | 0 | U | SF9---N | F | |
| DN | SMS | Z | 1 | EA | 0 | U | 9B----- | N |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|