| APTQ |
INPUT FREQUENCY RATING |
50.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 60.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| FEAT |
SPECIAL FEATURES |
COMPACT, HIGHLY REGULATED ADJUSTABLE-VOLTAGE AC POWER SOURCE USED TO TEST OR OPERATE 60/60 HZ EQUIPMENT WHERE THE NORMALLY AVAILABLE POWER SOURCE DOES NOT HAVE THE REQUISITE FREQUENCY, VOLTAGE STABILITY OR CAPACITY FOR WIDE ADJUSTMENT; SUPPLIED AS A CABINET MODEL, FINSIHED WITH GRAY WRINKLE PAINT WITH ANODIZED ALUMINUM FRONT PANEL; RF NOISE SUPRESSION BUILT IN; OUTPUT FREQUENCY IN 2 RANGES: 320 TO 560 HZ AND 560 TO 1000 HZ; OUTPUT VOLTAGE REGULATION +/- 1%; INPUT CURRENT AT FULL LOAD: 15 AMPS AT 1000 HZ OUTPUT; LOAD RANGE 0 TO 250 VA; OUTPUT DISTORTION 5% NOMINAL; POWER FACTOR RANGE; UNIT TO ZERO LAGGING; MODULATION 2% MAX; TECH ORDER 33A1-5-297-1 |
| ABKW |
OVERALL HEIGHT |
12.625 INCHES NOMINAL |
| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
OPERATING |
| AMQY |
INSTALLATION DESIGN |
BENCH |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
FREQUENCY CHANGER |
| ABMK |
OVERALL WIDTH |
15.438 INCHES NOMINAL |
| APTS |
OUTPUT FREQUENCY RATING |
320.0 HERTZ MINIMUM SINGLE POWER OUTPUT AND 1000.0 HERTZ MAXIMUM SINGLE POWER OUTPUT |
| APNX |
INPUT VOLTAGE RATING |
105.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 125.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
| ABHP |
OVERALL LENGTH |
19.312 INCHES NOMINAL |
| APPA |
OUTPUT VOLTAGE RATING |
115.0 AC VOLTS NOMINAL SINGLE POWER OUTPUT |