6130-00-264-5528 ( S971249 , S971249 , 104M6383 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 6130-00-264-5528 | 6130 | 002645528 | RECTIFIER,METALLIC | 0029 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| ADZC | ENVIRONMENTAL PROTECTION | OIL RESISTANT |
| ABJH | TEMP RATING | 35.0 DEG CELSIUS |
| MATL | MATERIAL | COPPER OXIDE |
| ASDS | GROUNDED TERMINAL | NOT INCLUDED |
| ASCY | DC OUTPUT MAXIMUM VOLTAGE RATING | 42.0 VOLTS NEW AND 36.0 VOLTS AGED |
| ASCX | LOAD TYPE | RESISTIVE |
| ANPZ | INCLOSURE FEATURE | ENCASED |
| ADJH | MOUNTING METHOD | BRACKET |
| ASCT | RMS INPUT MAXIMUM VOLTAGE RATING | 103.0 VOLTS |
| ASCW | DC OUTPUT MAXIMUM CURRENT RATING | 110.000 MILLIAMPERES |
| AJUR | CIRCUIT CONNECTION STYLE DESIGNATOR | CENTER TAP 1 PHASE |
| ABHP | OVERALL LENGTH | 6.250 INCHES NOMINAL |
| AARB | TERMINAL TYPE | THREADED STUD |
| ADAV | OVERALL DIAMETER | 1.625 INCHES NOMINAL |
| ALGC | MOUNTING CONFIGURATION | TWO 0.281 IN. BY 0.656 SLOTS 6.187 IN. C TO C |
| AARA | TERMINAL QUANTITY | 3 |
| ASCZ | STACK QUANTITY | 1 |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| S971249 | 79500 | A | 9 | 5 | X | XX | |
| S971249 | 11660 | H | 9 | 5 | X | XX | |
| 104M6383 | 14321 | A | 2 | 3 | A | CX |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| S971249 | 79500 | WESTINGHOUSE ELECTRIC CORP | A | A |
| S971249 | 11660 | WESTINGHOUSE ELECTRIC CORP | A | H |
| 104M6383 | 14321 | PD & E ELECTRONICS LLC | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | X | A | 01/01/1 | N | 8504409550 | 0029 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DN | 9B----- | N | |||
| DS | I |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | N | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DS | SMS | X | 1 | EA | 0 | U | D | ||
| DN | SMS | X | 1 | EA | 0 | U | 9B----- | N |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|