| CWHT |
INPUT CONNECTION QUANTITY |
2 2ND OPERATING POWER RQMT |
| CWHF |
OUTPUT CONNECTION QUANTITY |
4 2ND POWER OUTPUT |
| CWHF |
OUTPUT CONNECTION QUANTITY |
4 3RD POWER OUTPUT |
| CBBL |
FEATURES PROVIDED |
FILTER |
| ANPM |
INPUT PHASE |
SINGLE 2ND OPERATING POWER RQMT |
| CWGH |
OUTPUT CURRENT RATING |
1.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
OPERATING |
| APPA |
OUTPUT VOLTAGE RATING |
12.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 15.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
| APPA |
OUTPUT VOLTAGE RATING |
-15.0 DC VOLTS MINIMUM 3RD POWER OUTPUT AND -12.0 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
| BGHY |
OUTPUT CONTROL TYPE |
VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
| CWGH |
OUTPUT CURRENT RATING |
800.0 DC MILLIAMPERES MINIMUM 3RD POWER OUTPUT AND 1.0 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
| BGHX |
OUTPUT CONTROL QUANTITY |
1 1ST POWER OUTPUT |
| APTQ |
INPUT FREQUENCY RATING |
47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
| BGHX |
OUTPUT CONTROL QUANTITY |
1 2ND POWER OUTPUT |
| APPA |
OUTPUT VOLTAGE RATING |
5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
| BGHX |
OUTPUT CONTROL QUANTITY |
1 3RD POWER OUTPUT |
| CWHC |
OUTPUT CONTROL LOCATION |
FRONT PANEL 1ST POWER OUTPUT |
| BGHY |
OUTPUT CONTROL TYPE |
VOLTAGE ADJUSTMENT 3RD POWER OUTPUT |
| APTQ |
INPUT FREQUENCY RATING |
47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
| CWHQ |
INPUT CONNECTION TYPE |
TERMINAL STRIP 1ST OPERATING POWER RQMT |
| CWHC |
OUTPUT CONTROL LOCATION |
FRONT PANEL 2ND POWER OUTPUT |
| CWHJ |
OUTPUT CONNECTION TYPE |
TERMINAL STRIP 1ST POWER OUTPUT |
| ANPM |
INPUT PHASE |
SINGLE 1ST OPERATING POWER RQMT |
| CWHC |
OUTPUT CONTROL LOCATION |
FRONT PANEL 3RD POWER OUTPUT |
| ABMK |
OVERALL WIDTH |
4.000 INCHES NOMINAL |
| CWHJ |
OUTPUT CONNECTION TYPE |
TERMINAL STRIP 2ND POWER OUTPUT |
| CWHJ |
OUTPUT CONNECTION TYPE |
TERMINAL STRIP 3RD POWER OUTPUT |
| APNX |
INPUT VOLTAGE RATING |
125.0 AC POUNDS PER HOUR WET 2ND OPERATING POWER RQMT |
| ABKW |
OVERALL HEIGHT |
2.950 INCHES NOMINAL |
| CWHQ |
INPUT CONNECTION TYPE |
TERMINAL STRIP 2ND OPERATING POWER RQMT |
| CWHT |
INPUT CONNECTION QUANTITY |
2 1ST OPERATING POWER RQMT |
| ABHP |
OVERALL LENGTH |
10.250 INCHES NOMINAL |
| BGHY |
OUTPUT CONTROL TYPE |
VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
| AYNH |
OPERATING AMBIENT TEMP RANGE |
+0.1/+71.0 DEG CELSIUS |
| CWGH |
OUTPUT CURRENT RATING |
800.0 DC MILLIAMPERES MINIMUM 1ST POWER OUTPUT AND 1.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
| APNX |
INPUT VOLTAGE RATING |
230.0 AC POUNDS PER HOUR WET 1ST OPERATING POWER RQMT |
| CWHF |
OUTPUT CONNECTION QUANTITY |
4 1ST POWER OUTPUT |