| CWHF |
OUTPUT CONNECTION QUANTITY |
2 SINGLE POWER OUTPUT |
| APTQ |
INPUT FREQUENCY RATING |
50.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 400.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| BGHY |
OUTPUT CONTROL TYPE |
VOLTAGE ADJUSTMENT SINGLE POWER OUTPUT |
| CWHT |
INPUT CONNECTION QUANTITY |
2 SINGLE OPERATING POWER RQMT |
| ADZC |
ENVIRONMENTAL PROTECTION |
GENERAL PURPOSE |
| CWGW |
POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICS |
LIMITING CURRENT SINGLE POWER OUTPUT |
| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
OPERATING |
| ABHP |
OVERALL LENGTH |
9.250 INCHES NOMINAL |
| CBBL |
FEATURES PROVIDED |
REMOTE ERROR SENSING CAPABILITY AND OVER VOLTAGE PROTECTOR AND GROUND WIRE TERMINAL |
| AYNH |
OPERATING AMBIENT TEMP RANGE |
-20.0/+71.0 DEG CELSIUS |
| CWKG |
VENTILATION DESIGN TYPE |
CONVECTION |
| AJJY |
DOCUMENT SOURCE |
14749 |
| ABKW |
OVERALL HEIGHT |
1.680 INCHES NOMINAL |
| BGHX |
OUTPUT CONTROL QUANTITY |
1 SINGLE POWER OUTPUT |
| APNX |
INPUT VOLTAGE RATING |
105.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 125.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
| CWHJ |
OUTPUT CONNECTION TYPE |
SCREW SINGLE POWER OUTPUT |
| APPA |
OUTPUT VOLTAGE RATING |
24.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
| AMQY |
INSTALLATION DESIGN |
HOLE |
| ANPM |
INPUT PHASE |
SINGLE SINGLE OPERATING POWER RQMT |
| CWHQ |
INPUT CONNECTION TYPE |
SCREW SINGLE OPERATING POWER RQMT |
| CWGH |
OUTPUT CURRENT RATING |
1.25 DC AMPERES NOMINAL SINGLE POWER OUTPUT |
| ZZZV |
FSC APPLICATION DATA |
TEST SET,ELECT. EQUIP. |
| CWHC |
OUTPUT CONTROL LOCATION |
REAR PANEL SINGLE POWER OUTPUT |
| ABMK |
OVERALL WIDTH |
4.680 INCHES NOMINAL |
| CWGZ |
RIPPLE VOLTAGE AT FULL LOAD |
0.25 MILLIVOLTS RMS SINGLE POWER OUTPUT |