| BGQF |
POWER UNIT QUANTITY |
4 |
| CWHF |
OUTPUT CONNECTION QUANTITY |
8 SINGLE POWER OUTPUT |
| CWHJ |
OUTPUT CONNECTION TYPE |
TERMINAL STRIP SINGLE POWER OUTPUT |
| AQHL |
COMPONENT NAME |
POWER SUPPLY ASSEMBLY |
| ABKW |
OVERALL HEIGHT |
5.312 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
19.000 INCHES NOMINAL |
| APPA |
OUTPUT VOLTAGE RATING |
14.2 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 15.7 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
| APNX |
INPUT VOLTAGE RATING |
210.0 AC POUNDS PER HOUR DRY 1ST ALTERNATE OPERATING POWER RQMT AND 254.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST ALTERNATE OPERATING POWER RQMT |
| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
OPERATING |
| CWGH |
OUTPUT CURRENT RATING |
2.0 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 3.4 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
| AMKG |
POWER UNIT TYPE |
SILICON CONTROLLED RECTIFIER SINGLE OPERATING POWER RQMT |
| FEAT |
SPECIAL FEATURES |
OUTPUT TERM COVERS |
| ABHP |
OVERALL LENGTH |
14.000 INCHES NOMINAL |
| CWKG |
VENTILATION DESIGN TYPE |
CONVECTION |
| AGAV |
END ITEM IDENTIFICATION |
AN/FPS-117(V) |
| AJKA |
DOCUMENT IDENTIFICATION |
23211 |
| APPA |
OUTPUT VOLTAGE RATING |
14.2 DC VOLTS MINIMUM 3RD POWER OUTPUT AND 15.7 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
| AEAS |
MAJOR COMPONENTS |
RACK ADAPTER NSN 6130-01-162-5959MODEL LRA-15; POWER SUPPLY NSN 6130-01-084-3246 MODEL LNS-Y-5-OV; POWER SUPPLY MODEL LNS-X-28-42769; (2) POWER SUPPLIES 6130-01-138-1685 MODEL LNS-Y-15;(2) OVERVOLTAGE PROTECTOR 5962-01-087-2308 MODEL L-6-OV-15; OVERVOLTAGE PROTECTOR 5920-01-097-7526 MODEL L-12-OV-28 |
| APPA |
OUTPUT VOLTAGE RATING |
24.7 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 27.3 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
| CBBL |
FEATURES PROVIDED |
ON-OFF SWITCH-INDICATOR AND DIGITAL AMMETER AND DIGITAL VOLTMETER AND REMOTE ERROR SENSING CAPABILITY AND FUSE AND INPUT TO CASE ISOLATION AND INPUT TO OUTPUT ISOLATION AND OVER VOLTAGE PROTECTOR AND VOLTAGE ADJUSTMENT AND OVER CURRENT PROTECTOR AND OUTPUT TO CASE ISOLATION AND OVER TEMPERATURE PROTECTION |
| APNX |
INPUT VOLTAGE RATING |
105.0 AC POUNDS PER HOUR DRY 2ND ALTERNATE OPERATING POWER RQMT AND 127.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND ALTERNATE OPERATING POWER RQMT |
| AQHK |
COMPONENT CONTROLLING AGENCY |
LAMBDA ELECT |
| APTQ |
INPUT FREQUENCY RATING |
47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| AQHM |
COMPONENT IDENTIFYING NUMBER |
23211 DRAWING NO. |
| CWGH |
OUTPUT CURRENT RATING |
3.1 DC AMPERES MINIMUM 4TH POWER OUTPUT AND 6.0 DC AMPERES MAXIMUM 4TH POWER OUTPUT |
| AYNH |
OPERATING AMBIENT TEMP RANGE |
-0.0/+71.0 DEG CELSIUS |
| CWGH |
OUTPUT CURRENT RATING |
2.4 DC AMPERES NOMINAL 1ST POWER OUTPUT |
| CWGH |
OUTPUT CURRENT RATING |
2.0 DC AMPERES MINIMUM 3RD POWER OUTPUT AND 3.4 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
| ADZC |
ENVIRONMENTAL PROTECTION |
FUNGUS PROOF |
| ANPM |
INPUT PHASE |
SINGLE SINGLE OPERATING POWER RQMT |
| AJJY |
DOCUMENT SOURCE |
80103 |
| APPA |
OUTPUT VOLTAGE RATING |
4.7 DC VOLTS MINIMUM 4TH POWER OUTPUT AND 5.2 DC VOLTS MAXIMUM 4TH POWER OUTPUT |