| CWGH |
OUTPUT CURRENT RATING |
12.5 DC AMPERES MINIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS AND 21.5 DC AMPERES MAXIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| CWKG |
VENTILATION DESIGN TYPE |
SINGLE FAN |
| ABMK |
OVERALL WIDTH |
19.000 INCHES NOMINAL |
| AGAV |
END ITEM IDENTIFICATION |
AN/MPQ-T3; E/I 6940-01-042-9823 |
| SUWT |
UNIT OF ISSUE WEIGHT |
73.75 POUNDS |
| ABHP |
OVERALL LENGTH |
21.125 INCHES NOMINAL |
| BGHY |
OUTPUT CONTROL TYPE |
COARSE VOLTAGE ADJUSTMENT MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS AND CURRENT LIMIT MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS AND SWITCH MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS AND VOLTAGE ADJUSTMENT MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| AMQY |
INSTALLATION DESIGN |
SLIDE SUPPORT |
| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
OPERATING |
| NHCF |
NUCLEAR HARDNESS CRITICAL FEATURE |
NONHARDENED |
| ABKW |
OVERALL HEIGHT |
5.219 INCHES NOMINAL |
| CBBL |
FEATURES PROVIDED |
OVER VOLTAGE PROTECTOR AND EMI FILTER AND DC VOLTMETER AND DC AMMETER AND OVER TEMPERATURE PROTECTION AND REMOTE CONTROL AND REMOTE ERROR SENSING CAPABILITY AND VOLTAGE ADJUSTMENT AND FUNCTION SWITCH |
| AMKG |
POWER UNIT TYPE |
SILICON CONTROLLED RECTIFIER SINGLE OPERATING POWER RQMT |
| APTQ |
INPUT FREQUENCY RATING |
47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| FEAT |
SPECIAL FEATURES |
CONSISTS OF POWER SUPPLY P/N LT-804 NSN 6130-01-288-2491 QTY 2; P/N LRA-17-CS RACK ADAPTOR WITH CHASSIS SLIDES QTY 1 |
| CWHM |
INPUT CURRENT RATING |
18.0 AC AMPERES NOMINAL SINGLE OPERATING POWER RQMT |
| BGHX |
OUTPUT CONTROL QUANTITY |
3 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| APNX |
INPUT VOLTAGE RATING |
187.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 242.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
| APPA |
OUTPUT VOLTAGE RATING |
0.0 DC VOLTS MINIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS AND 60.0 DC VOLTS MAXIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| CWHT |
INPUT CONNECTION QUANTITY |
3 SINGLE OPERATING POWER RQMT |
| CWWY |
POWER SUPPLY EFFICIENCY LINE |
65.0 |
| CWWJ |
PROGRAM COMPATIBILITY |
IEEE-488 COMPATIBLE |
| AYNH |
OPERATING AMBIENT TEMP RANGE |
-0.0/+71.0 DEG CELSIUS |
| CWHC |
OUTPUT CONTROL LOCATION |
FRONT PANEL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| CWHF |
OUTPUT CONNECTION QUANTITY |
2 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| ANPM |
INPUT PHASE |
SINGLE SINGLE OPERATING POWER RQMT |
| CWHQ |
INPUT CONNECTION TYPE |
TERMINAL STRIP SINGLE OPERATING POWER RQMT |
| CWHJ |
OUTPUT CONNECTION TYPE |
BUS (BAR) CONDUCTOR MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| BGQF |
POWER UNIT QUANTITY |
2 |