6130-01-346-5836 ( 8949111 , SYS-3081 , 8949111-01-1 , 8949111-01 )

NSN Information
NSN FSC NIIN Item Name INC
6130-01-346-5836 6130 013465836 POWER SUPPLY 0074
NSN Features
MRC Parameter Characteristics
ABKW OVERALL HEIGHT 3.500 INCHES NOMINAL
APNX INPUT VOLTAGE RATING 103.5 AC POUNDS PER HOUR DRY 2ND ALTERNATE OPERATING POWER RQMT AND 207.0 AC POUNDS PER HOUR DRY 1ST ALTERNATE OPERATING POWER RQMT AND 126.5 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND ALTERNATE OPERATING POWER RQMT
APPA OUTPUT VOLTAGE RATING 12.97 DC VOLTS MAXIMUM 4TH POWER OUTPUT
APPA OUTPUT VOLTAGE RATING 5.25 DC VOLTS MAXIMUM 5TH POWER OUTPUT
CWKG VENTILATION DESIGN TYPE SINGLE FAN
AYNH OPERATING AMBIENT TEMP RANGE -40.0/+71.0 DEG CELSIUS
APTQ INPUT FREQUENCY RATING 52.5 HERTZ MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT
ABMK OVERALL WIDTH 7.250 INCHES NOMINAL
APPA OUTPUT VOLTAGE RATING 14.65 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 14.65 DC VOLTS MINIMUM 3RD POWER OUTPUT AND -14.65 DC VOLTS MINIMUM 6TH POWER OUTPUT AND 12.22 DC VOLTS MINIMUM 4TH POWER OUTPUT AND 26.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 4.04 DC VOLTS MINIMUM 5TH POWER OUTPUT AND 15.55 DC VOLTS MAXIMUM 3RD POWER OUTPUT
CWGH OUTPUT CURRENT RATING 5.0 DC AMPERES NOMINAL 4TH POWER OUTPUT
AKWC ELECTRICAL POWER SOURCE RELATIONSHIP OPERATING
APNX INPUT VOLTAGE RATING 253.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST ALTERNATE OPERATING POWER RQMT
CWGH OUTPUT CURRENT RATING -2.0 DC AMPERES NOMINAL 6TH POWER OUTPUT
CWHJ OUTPUT CONNECTION TYPE CONNECTOR, RECEPTACLE SINGLE POWER OUTPUT
APPA OUTPUT VOLTAGE RATING 15.55 DC VOLTS MAXIMUM 2ND POWER OUTPUT
CWHF OUTPUT CONNECTION QUANTITY 1 SINGLE POWER OUTPUT
ABHP OVERALL LENGTH 10.000 INCHES NOMINAL
AGAV END ITEM IDENTIFICATION AN/USM-638; USED ON 8949102
CWGH OUTPUT CURRENT RATING 16.0 DC AMPERES NOMINAL 5TH POWER OUTPUT
CWHT INPUT CONNECTION QUANTITY 1 SINGLE OPERATING POWER RQMT
CWGH OUTPUT CURRENT RATING 4.0 DC AMPERES NOMINAL 2ND POWER OUTPUT
APPA OUTPUT VOLTAGE RATING 30.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT
APPA OUTPUT VOLTAGE RATING -15.55 DC VOLTS MAXIMUM 6TH POWER OUTPUT
CWGH OUTPUT CURRENT RATING 3.0 DC AMPERES NOMINAL 1ST POWER OUTPUT
APTQ INPUT FREQUENCY RATING 420.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
CWGH OUTPUT CURRENT RATING 2.5 DC AMPERES NOMINAL 3RD POWER OUTPUT
CWWY POWER SUPPLY EFFICIENCY LINE 70.0
CRTL CRITICALITY CODE JUSTIFICATION FEAT
CWHQ INPUT CONNECTION TYPE CONNECTOR, PLUG SINGLE OPERATING POWER RQMT
ADZC ENVIRONMENTAL PROTECTION FUNGUS PROOF
ANPM INPUT PHASE SINGLE SINGLE OPERATING POWER RQMT
APTQ INPUT FREQUENCY RATING 57.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 47.5 HERTZ MINIMUM 3RD ALTERNATE OPERATING POWER RQMT AND 380.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
FEAT SPECIAL FEATURES ELECTROSTATIC SENSITIVE DEVICE
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
8949111 98750 R 9 D 2 MB
SYS-3081 61814 A 2 3 2 ZZ
8949111-01-1 94117 A 2 5 2 MB
8949111-01 94117 A 2 5 2 ZZ
Manufacturers
Part SKU Cage Manufacturer Type Status
8949111 98750 SAN ANTONIO AIR LOGISTICS CENTER A R
SYS-3081 61814 ATC POWER SYSTEMS INC. F A
8949111-01-1 94117 BAE SYSTEMS INFORMATION AND A A
8949111-01 94117 BAE SYSTEMS INFORMATION AND A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
U 0 Y B 3 10/08/1 N 8504900080 0074
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DF T SF8QC-N L
DN H 7REWAR2 N R REFER TO NET PRICE 6014.00
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
B U N 0 Y
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DN NRP C 1 EA 0 U 7REWAR2 N
DF FLZ C 1 EA 0 U SF8QC-N L
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
062900 X 35110 M M 72D Z Z A H Z RECTIFIERS NOI/BATTERY ELIMINATORS