| ANPM |
INPUT PHASE |
SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
| CWGH |
OUTPUT CURRENT RATING |
1.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
| CWHF |
OUTPUT CONNECTION QUANTITY |
1 2ND POWER OUTPUT |
| CWHJ |
OUTPUT CONNECTION TYPE |
PIN PLUG 1ST POWER OUTPUT |
| CWHF |
OUTPUT CONNECTION QUANTITY |
1 3RD POWER OUTPUT |
| APPA |
OUTPUT VOLTAGE RATING |
0.1 DC VOLTS NOMINAL 3RD POWER OUTPUT |
| CWGH |
OUTPUT CURRENT RATING |
1.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
| ANPM |
INPUT PHASE |
SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
| CWHJ |
OUTPUT CONNECTION TYPE |
PIN PLUG 2ND POWER OUTPUT |
| CWGH |
OUTPUT CURRENT RATING |
1.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
| CWHJ |
OUTPUT CONNECTION TYPE |
PIN PLUG 3RD POWER OUTPUT |
| APPA |
OUTPUT VOLTAGE RATING |
10.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
OPERATING |
| APNX |
INPUT VOLTAGE RATING |
100.0 AC POUNDS PER HOUR DRY 1ST ALTERNATE OPERATING POWER RQMT AND 130.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST ALTERNATE OPERATING POWER RQMT |
| CBBL |
FEATURES PROVIDED |
PROGRAMMABLE AND DIGITAL AMMETER AND DIGITAL VOLTMETER AND OVER VOLTAGE PROTECTOR AND OVER TEMPERATURE PROTECTION |
| AGAV |
END ITEM IDENTIFICATION |
WRTTM SE-TEST SET |
| APPA |
OUTPUT VOLTAGE RATING |
5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
| APTQ |
INPUT FREQUENCY RATING |
50.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 60.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
| AYNH |
OPERATING AMBIENT TEMP RANGE |
+0.1/+50.0 DEG CELSIUS |
| CWHC |
OUTPUT CONTROL LOCATION |
REAR PANEL 1ST POWER OUTPUT |
| CWHC |
OUTPUT CONTROL LOCATION |
REAR PANEL 2ND POWER OUTPUT |
| CWHT |
INPUT CONNECTION QUANTITY |
1 1ST ALTERNATE OPERATING POWER RQMT |
| CWHC |
OUTPUT CONTROL LOCATION |
REAR PANEL 3RD POWER OUTPUT |
| APNX |
INPUT VOLTAGE RATING |
200.0 AC POUNDS PER HOUR DRY 2ND ALTERNATE OPERATING POWER RQMT AND 250.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND ALTERNATE OPERATING POWER RQMT |
| ABHP |
OVERALL LENGTH |
19.000 INCHES NOMINAL |
| CWHQ |
INPUT CONNECTION TYPE |
BINDING POST 1ST ALTERNATE OPERATING POWER RQMT |
| APTQ |
INPUT FREQUENCY RATING |
50.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 60.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
| CWHM |
INPUT CURRENT RATING |
20.0 AC AMPERES NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
| CWHM |
INPUT CURRENT RATING |
10.0 AC AMPERES NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
| ABKW |
OVERALL HEIGHT |
1.710 INCHES NOMINAL |
| CWKG |
VENTILATION DESIGN TYPE |
INTERNAL BLOWER |
| CWHT |
INPUT CONNECTION QUANTITY |
1 2ND ALTERNATE OPERATING POWER RQMT |
| CWHF |
OUTPUT CONNECTION QUANTITY |
1 1ST POWER OUTPUT |
| ABMK |
OVERALL WIDTH |
20.000 INCHES NOMINAL |
| CWHQ |
INPUT CONNECTION TYPE |
BINDING POST 2ND ALTERNATE OPERATING POWER RQMT |