| CWHF |
OUTPUT CONNECTION QUANTITY |
2 SINGLE POWER OUTPUT |
| APNX |
INPUT VOLTAGE RATING |
103.5 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 253.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
OPERATING |
| ABKW |
OVERALL HEIGHT |
2.070 INCHES NOMINAL |
| CBBL |
FEATURES PROVIDED |
CIRCUIT OVERLOAD PROTECTION DEVICE AND VOLTAGE ADJUSTMENT |
| AYNH |
OPERATING AMBIENT TEMP RANGE |
+0.1/+50.0 DEG CELSIUS |
| CWKG |
VENTILATION DESIGN TYPE |
CONVECTION |
| ABMK |
OVERALL WIDTH |
4.000 INCHES NOMINAL |
| APTQ |
INPUT FREQUENCY RATING |
47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| ABHP |
OVERALL LENGTH |
4.870 INCHES NOMINAL |
| APPA |
OUTPUT VOLTAGE RATING |
24.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
| CWGH |
OUTPUT CURRENT RATING |
1.2 DC AMPERES NOMINAL SINGLE POWER OUTPUT |
| FEAT |
SPECIAL FEATURES |
OUPUT CURRENT DERATED 10.0 PERCENT FOR 50 HZ OPERATION; DC OUTPUT ADJUSTMENT RANGE PLUS OR MINUS 5.0 PERCENT MINIMUM; OUTPUT RIPPLE 0.02 PERCENT PEAK TO PEAK, 0.01 PERCENT RMS MAXIMUM; FOLDBACK CURRENT LIMIT WITH AUTOMATIC RECOVERY; STABILITY, PLUS OR MINUS 0.3 PERCENT FOR 24 HOURS AFTER WARMUP; TEMPERATURE RATING IS DERATED LINEARLY FROM FULL RATED AT 50 DEGREES C TO 40.0 PERCENT AT 70 DEGREES C; VIBRATION RESISTANT PER MIL-STD-810B, METHOD 514, PROCEDURE 1, CURVE AB (TO 50 HZ); SHOCK RESISTANT PER MIL-STD-810B, METHOD 516, PROCEDURE V; IC REGULATED DESIGN; 2 HOUR BURN-IN; MOVING AIR OR CONDUCTION COOLING RECOMMENDED IF IN CONFINED AREA |