| APPA |
OUTPUT VOLTAGE RATING |
12.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
| APNX |
INPUT VOLTAGE RATING |
100.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 240.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
| FEAT |
SPECIAL FEATURES |
1WILL ACCEPT 100,120,220,230,AND 240 VAC INPUT; ANTI-LATCH CIRCUITRY TO HANDLE HIGH SURGE AND CROSS COUPLED LOADS; OPERATING TEMPERATURE FROM 0 TO PLUS 50 DEG. C; STORAGE TEMPERATURE MINUS 20 TO PLUS 85 DEG. C; DIELECTRIC WITHSTAND VOLTAGE IS 3750 VAC INPUT TO GROUND - INPUT TO OUTPUT AND 700 VDC OUTPUT TO GROUND; REVERSE VOLTAGE PROTECTION PROVIDED ON OUTPUTS AND PASS ELEMENTS; SHOCK AND VIBRATION TESTED PER MIL-STD-810E; MEET UL 1950, CSA 22.2 NO. 234, EN 60 950, AND IEC 950 SAFETY STANDARDS |
| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
OPERATING |
| CWHF |
OUTPUT CONNECTION QUANTITY |
4 SINGLE POWER OUTPUT |
| APTQ |
INPUT FREQUENCY RATING |
47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| CWHQ |
INPUT CONNECTION TYPE |
SOLDER LUG SINGLE OPERATING POWER RQMT |
| CWGZ |
RIPPLE VOLTAGE AT FULL LOAD |
1.0 MILLIVOLTS RMS SINGLE POWER OUTPUT AND 5.0 MILLIVOLTS PEAK SINGLE POWER OUTPUT |
| ABHP |
OVERALL LENGTH |
4.880 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
4.000 INCHES NOMINAL |
| CWHJ |
OUTPUT CONNECTION TYPE |
SCREW SINGLE POWER OUTPUT |
| CWGH |
OUTPUT CURRENT RATING |
1.7 DC AMPERES NOMINAL SINGLE POWER OUTPUT |
| ANPM |
INPUT PHASE |
SINGLE SINGLE OPERATING POWER RQMT |
| ABKW |
OVERALL HEIGHT |
2.280 INCHES NOMINAL |