| FEAT |
SPECIAL FEATURES |
OUTPUT CONFIGURATION MONOPHASE SINEWAVE; EFFICIENCY 75 PCT NOMINAL; UNIT HAS REVERSE POLARITY PROTECTION; FREQUENCY MONITOR AUTOMATICALLY SHUTS THE INVERTER OFF SHOULD THE FREQUENCY DRIFT BELOW 370 HZ OR ABOVE 430 HZ; FAULTMONITOR PROVIDES 27 VDC OUTPUT AT 100 MA TO AN ANNUNCIATOR DEVICE UNDER NORMAL CONDITION; NO POWER IS AVAILABLE UNDER FAULT CONDITIONS; COOLING HI-REL BLOWER; ENVIRONMENTAL CONDITIONS RFI EMISSION MEETS RTCA DO-160A CAT Z; MATING CONNECTOR MS3476L14-9S |
| AGAV |
END ITEM IDENTIFICATION |
FIXED WING AND HELICOPTER QUALIFIED |
| ABKW |
OVERALL HEIGHT |
69.9 MILLIMETERS NOMINAL |
| ABMK |
OVERALL WIDTH |
127.0 MILLIMETERS NOMINAL |
| APNX |
INPUT VOLTAGE RATING |
24.0 DC VOLTS MINIMUM 2ND OPERATING POWER RQMT AND 32.0 DC VOLTS MAXIMUM 2ND OPERATING POWER RQMT |
| ABHP |
OVERALL LENGTH |
177.8 MILLIMETERS NOMINAL |
| APPA |
OUTPUT VOLTAGE RATING |
26.0 AC VOLTS NOMINAL 2ND POWER OUTPUT |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
PC-251-123A LIGHTWEIGHT STATIC INVERTER |
| AYNH |
OPERATING AMBIENT TEMP RANGE |
-55.0/+71.0 DEG CELSIUS |
| CWHM |
INPUT CURRENT RATING |
11.9 DC AMPERES NOMINAL 1ST OPERATING POWER RQMT |
| APNX |
INPUT VOLTAGE RATING |
28.0 DC VOLTS NOMINAL 1ST OPERATING POWER RQMT |
| APPA |
OUTPUT VOLTAGE RATING |
115.0 AC VOLTS NOMINAL 1ST POWER OUTPUT |
| AKAE |
MAXIMUM OPERATING ALTITUDE RATING |
50000.0 FEET |
| AMQY |
INSTALLATION DESIGN |
BOLT |