| CWHM |
INPUT CURRENT RATING |
4.0 AC AMPERES MAXIMUM 2ND OPERATING POWER RQMT |
| AGAV |
END ITEM IDENTIFICATION |
SWITCH; SERVER CABINET ASSEMBLY U29 & U32. |
| APPA |
OUTPUT VOLTAGE RATING |
5.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
| CWKG |
VENTILATION DESIGN TYPE |
SINGLE FAN |
| ANPM |
INPUT PHASE |
SINGLE 2ND OPERATING POWER RQMT |
| FEAT |
SPECIAL FEATURES |
115VAC/230VAC SWITCHABLE; OPERATION TEMPERATURE 0-50 DEGREES C; OVERPOWER PROTECTION 105% TO 140%; SHORT CIRCUIT PROTECTION IS SHUT DOWN. DEMENSION=HXWXD: 86X150X140MM; 300 WATT GENERAL PURPOSE POWER SUPPLY. |
| APNX |
INPUT VOLTAGE RATING |
115.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST OPERATING POWER RQMT |
| APPA |
OUTPUT VOLTAGE RATING |
12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
INAVY: POWER SUPPLY |
| APPA |
OUTPUT VOLTAGE RATING |
-5.0 DC VOLTS NOMINAL 4TH POWER OUTPUT |
| CWGZ |
RIPPLE VOLTAGE AT FULL LOAD |
120.0 MILLIVOLTS PEAK SINGLE POWER OUTPUT |
| APTQ |
INPUT FREQUENCY RATING |
60.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
| BGQR |
OUTPUT WATTAGE RATING |
300.0 WATTS NOMINAL SINGLE POWER OUTPUT |
| APNX |
INPUT VOLTAGE RATING |
230.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND OPERATING POWER RQMT |
| ANPM |
INPUT PHASE |
SINGLE 1ST OPERATING POWER RQMT |
| ABHP |
OVERALL LENGTH |
140.0 MILLIMETERS NOMINAL |
| APPA |
OUTPUT VOLTAGE RATING |
-12.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
| CWWY |
POWER SUPPLY EFFICIENCY LINE |
72.0 |
| APTQ |
INPUT FREQUENCY RATING |
60.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
| CWHM |
INPUT CURRENT RATING |
8.0 AC AMPERES MAXIMUM 1ST OPERATING POWER RQMT |