6140-00-227-8555 ( JC12250 , EP12240 , PS-12200 , 1004913-2 , 1004913-03 , 138C682H01 , GC12230-6 , 1004913-01 , EP12240-34 , 1004913-02 , GC12200A , 1004913-03 , GC12230 , GC12230-6A , GC12230TYPE A , GC12200 TYPE B )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 6140-00-227-8555 | 6140 | 002278555 | BATTERY,STORAGE | 0001 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CWFH | CASE DESIGN TYPE | SEALED |
| ARGW | PLATE TYPE | NEGATIVE AND POSITIVE |
| AQHD | NONSPILLING FEATURE | NOT INCLUDED |
| AQHJ | INTEGRAL CHARGING FACILITY | NOT INCLUDED |
| AEXT | BATTERY ELECTROLYTE | SILICA-GEL |
| AQGM | DISCHARGE TIME IN MINUTES | 1200.0 |
| ABJH | TEMP RATING | 60.0 DEG CELSIUS |
| ABKW | OVERALL HEIGHT | 4.920 INCHES NOMINAL |
| AQHF | CHARGE INDICATOR | NOT INCLUDED |
| ABHP | OVERALL LENGTH | 6.590 INCHES NOMINAL |
| AQGR | PLATE MATERIAL | CALCIUM LEAD |
| AQHG | ELECTROLYTE LEVEL INDICATOR | NOT INCLUDED |
| AARA | TERMINAL QUANTITY | 2 |
| AQHE | DISCHARGE RATE IN AMPS | 1.00 |
| AQHH | STORAGE/SHIPMENT CONDITION | WET CHARGED |
| AQGL | TIME CAPACITY IN HOURS | 20.00 |
| AQGS | PLATE QUANTITY PER CELL | 6 |
| ABMK | OVERALL WIDTH | 6.940 INCHES NOMINAL |
| ADTV | CASE MATERIAL | PLASTIC, POLYSTYRENE |
| ELEC | VOLTAGE IN VOLTS | 12.0 |
| AQGQ | CELL QUANTITY | 6 |
| AGEB | FORDING FEATURE | NOT INCLUDED |
| AQGN | LOW TEMP AMPERE HOUR CAPACITY | 20.00 |
| ADTC | SEPARATOR MATERIAL | PLASTIC |
| AQGK | AMPERE HOUR CAPACITY | 23.00 |
| AARB | TERMINAL TYPE | QUICK DISCONNECT W/LEADS |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| JC12250 | 25244 | A | 2 | 3 | 5 | CX | |
| EP12240 | 31743 | H | 9 | 5 | 5 | CX | |
| PS-12200 | 56309 | A | 9 | 5 | 3 | CX | |
| 1004913-2 | 36378 | R | 9 | 5 | 1 | CX | |
| 1004913-03 | 1PQF4 | A | 2 | 7 | 5 | ZZ | |
| 138C682H01 | 97942 | A | 1 | C | 9 | 48 | |
| GC12230-6 | 25244 | A | 2 | 3 | 2 | SB | |
| 1004913-01 | 36378 | R | 9 | 5 | 2 | MC | |
| EP12240-34 | 31743 | H | 9 | 5 | E | CX | |
| 1004913-02 | 36378 | R | 9 | 5 | 2 | MC | |
| GC12200A | 25244 | A | 9 | 5 | 5 | CX | |
| 1004913-03 | 36378 | R | 9 | 5 | 2 | MC | |
| GC12230 | 25244 | A | 9 | 5 | 5 | CX | |
| GC12230-6A | 25244 | A | 9 | 5 | 5 | CX | |
| GC12230TYPE A | 25244 | A | 9 | 5 | 5 | CX | |
| GC12200 TYPE B | 25244 | A | 9 | 5 | 2 | CX |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| JC12250 | 25244 | JOHNSON CONTROLS INC. | F | A |
| EP12240 | 31743 | ELDON INDUSTRIES INC | A | H |
| PS-12200 | 56309 | POWER-SONIC CORPORATION | A | A |
| 1004913-2 | 36378 | RAYTHEON TECHNICAL SERVICES COMP | A | R |
| 1004913-03 | 1PQF4 | L-3 COMMUNICATIONS CORPORATION | A | A |
| 138C682H01 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORA | A | A |
| GC12230-6 | 25244 | JOHNSON CONTROLS INC. | F | A |
| 1004913-01 | 36378 | RAYTHEON TECHNICAL SERVICES COMP | A | R |
| EP12240-34 | 31743 | ELDON INDUSTRIES INC | A | H |
| 1004913-02 | 36378 | RAYTHEON TECHNICAL SERVICES COMP | A | R |
| GC12200A | 25244 | JOHNSON CONTROLS INC. | F | A |
| 1004913-03 | 36378 | RAYTHEON TECHNICAL SERVICES COMP | A | R |
| GC12230 | 25244 | JOHNSON CONTROLS INC. | F | A |
| GC12230-6A | 25244 | JOHNSON CONTROLS INC. | F | A |
| GC12230TYPE A | 25244 | JOHNSON CONTROLS INC. | F | A |
| GC12200 TYPE B | 25244 | JOHNSON CONTROLS INC. | F | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | X | A | 05/20/1 | Y | 8507800000 | 0001 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DN | 9G----C | N | V | DISCONTINUED W/O REPLACEMENT |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | Y | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DN | S9G | Y | 1 | EA | 0 | U | 9G----C | N |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 060680 | Z | 34100 | W | 582 | V | 9 | A | H | Z | BATTERIES OR CELL |