6240-00-155-7932 ( 311R , 311R , 1068R311 , 311R , MS25235-R311 , 311R , 87-0143 , MS25235-311R , AML-311 R , AN3133R31 , 311R , 311R , ML311R , WL-311R , MS35235R311 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 6240-00-155-7932 | 6240 | 001557932 | LAMP,INCANDESCENT | 0072 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CWBF | RATED AVERAGE LIFE | HOURS |
| AFSV | AVERAGE LIFE RATING IN HOURS | 300.0 |
| AMSE | VOLTAGE RATING | 28.000 VOLTS NOMINAL |
| CWGK | BURNING POSITION | ANY ACCEPTABLE |
| AFSX | FILAMENT HEAVY DUTY SERVICE RATING | NOT RATED |
| ABHP | OVERALL LENGTH | 2.375 INCHES MAXIMUM |
| CSMC | BULB LIGHT TRANSMISSION CHARACTERISTIC | TRANSLUCENT |
| CRPS | BASE STYLE | SINGLE CONTACT BAYONET CANDELABRA |
| AGDW | LIGHT CENTER LENGTH | 1.250 INCHES NOMINAL |
| AFSP | FILAMENT DESIGNATION | C-2V |
| CSJW | BULB DESIGNATOR | S-11 |
| CRSK | BULB STYLE | S (STRAIGHT SIDE) |
| AFST | LIGHT OUTPUT RATING | 50.000 SPHERICAL CANDLEPOWER NOMINAL SINGLE RATING |
| CTQM | CURRENT RATING FOR WHICH DESIGNED | 1.290 AMPERES NOMINAL |
| FEAT | SPECIAL FEATURES | RATED CANDLEPOWER APPLIES TO LAMP BEFORE RED COATING IS APPLIED |
| BDWW | WATTAGE RATING | 36.000 WATTS |
| AGDV | EMITTED LIGHT CHARACTERISTIC | RED |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 311R | 94988 | A | 9 | 5 | 4 | CX | |
| 311R | 08108 | M | 1 | 5 | 4 | CX | |
| 1068R311 | 80020 | A | 1 | 5 | 5 | CX | |
| 311R | 08806 | F | 9 | 5 | E | CX | |
| MS25235-R311 | 96906 | M | 2 | 2 | 4 | CX | |
| 311R | 62607 | A | 1 | 5 | 4 | CX | |
| 87-0143 | 63409 | A | 1 | 5 | E | CX | |
| MS25235-311R | 81349 | M | 9 | 5 | E | ZZ | |
| AML-311 R | 0RAS6 | A | 2 | 5 | 5 | 9Z | |
| AN3133R31 | 88044 | M | 9 | 5 | 5 | SB | |
| 311R | 61951 | A | 1 | 5 | 5 | ZZ | |
| 311R | R1120 | A | 2 | 5 | 6 | ZG | |
| ML311R | 61951 | A | 9 | 5 | 5 | 9Z | |
| WL-311R | 58774 | A | 1 | 5 | 5 | ZZ | |
| MS35235R311 | 96906 | M | 1 | C | AC | 6 | ZZ |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 311R | 94988 | COOPER INDUSTRIES INC | A | A |
| 311R | 08108 | LAMP INDUSTRY | A | M |
| 1068R311 | 80020 | NAVAL AIR WARFARE CENTER AIRCRAF | A | A |
| 311R | 08806 | GENERAL ELECTRIC CO | A | F |
| MS25235-R311 | 96906 | MILITARY STANDARDS | A | M |
| 311R | 62607 | PHILIPS ELECTRONICS NORTH AMERIC | F | A |
| 87-0143 | 63409 | TREMETRICS INC | A | A |
| MS25235-311R | 81349 | MILITARY SPECIFICATIONS | A | M |
| AML-311 R | 0RAS6 | ADVANCED MICRO LITES INC | A | A |
| AN3133R31 | 88044 | AERONAUTICAL STANDARDS GROUP | A | M |
| 311R | 61951 | MICRO LAMPS INC. | A | A |
| 311R | R1120 | SATAIR A/S | E | A |
| ML311R | 61951 | MICRO LAMPS INC. | A | A |
| WL-311R | 58774 | WAMCO INC | A | A |
| MS35235R311 | 96906 | MILITARY STANDARDS | A | M |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | X | A | 1 | 01/01/1 | P | 9405400000 | 0072 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DM | Z | 15B2--- | M | ||
| GP | ------- | C | |||
| DN | 9B----- | N | |||
| DF | N | SF9SX-V | F | ||
| DS | N | I | |||
| DA | Z | J2200X- | A |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | P | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| GP | SMS | D | 1 | EA | 0 | U | ------- | C | |
| DS | SMS | D | 1 | EA | 0 | U | D | ||
| DA | SMS | D | 1 | EA | 0 | U | Z | J2200X- | A |
| DM | SMS | D | 1 | EA | 0 | U | Z | 15B2--- | M |
| DN | SMS | D | 1 | EA | 0 | U | 9B----- | N | |
| DF | SMS | D | 1 | EA | 0 | U | SF9SX-V | F |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|---|---|---|---|
| J | 2 | 2 | 00 | X |
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 109550 | X | 55910 | F | 658 | Z | 9 | A | H | Z | LAMPS(BULBS) ELEC INCANDESCENT NOI |