6240-01-089-6149 ( F48T12/CW/EW , W-L-00116/36A , F48T12SW , F48T12/CW/SS , F48T12/CW/WM , FR8T12/SW , 218917 , F48T12SW , 387001 , F48T12SW , F48T12SW , F48T12SW )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 6240-01-089-6149 | 6240 | 010896149 | LAMP,FLUORESCENT | 0389 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| AFSV | AVERAGE LIFE RATING IN HOURS | 9000.0 |
| CWBF | RATED AVERAGE LIFE | HOURS |
| ABHP | OVERALL LENGTH | 48.000 INCHES NOMINAL |
| CSJW | BULB DESIGNATOR | T-12 |
| AFST | LIGHT OUTPUT RATING | 2550.000 LUMENS MAXIMUM SINGLE RATING |
| AGDV | EMITTED LIGHT CHARACTERISTIC | WHITE, COOL |
| AMSE | VOLTAGE RATING | NOT RATED |
| FEAT | SPECIAL FEATURES | ENERGY SAVER |
| BDWW | WATTAGE RATING | 30.000 WATTS |
| CRSK | BULB STYLE | T (TUBULAR) |
| CRPS | BASE STYLE | SINGLE PIN (FLUORESCENT) |
| ARQF | STARTING CHARACTERISTIC | INSTANT |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| F48T12/CW/EW | 62607 | A | 9 | 5 | E | CX | |
| W-L-00116/36A | 81348 | M | 9 | 5 | 4 | CX | |
| F48T12SW | 04655 | A | 9 | 5 | 5 | ZZ | |
| F48T12/CW/SS | 88204 | A | 2 | 3 | E | CX | |
| F48T12/CW/WM | 08805 | A | 2 | 3 | 4 | 54 | |
| FR8T12/SW | 06172 | F | 9 | 5 | 5 | ZZ | |
| 218917 | 62607 | A | 9 | 5 | 5 | ZZ | |
| F48T12SW | 85271 | F | 9 | 5 | 5 | ZZ | |
| 387001 | 77569 | C | 2 | 5 | 5 | ZZ | |
| F48T12SW | 08599 | F | 9 | 5 | 5 | ZZ | |
| F48T12SW | 06RZ4 | A | 2 | 3 | 5 | ZZ | |
| F48T12SW | 08108 | M | 9 | 5 | 5 | ZZ |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| F48T12/CW/EW | 62607 | PHILIPS ELECTRONICS NORTH AMERIC | F | A |
| W-L-00116/36A | 81348 | FEDERAL SPECIFICATIONS | A | M |
| F48T12SW | 04655 | GENERAL DYNAMICS C4 SYSTEMS INC. | F | A |
| F48T12/CW/SS | 88204 | GTE PRODUCTS CORP | A | A |
| F48T12/CW/WM | 08805 | GENERAL ELECTRIC COMPANY | F | A |
| FR8T12/SW | 06172 | MARVEL LAMP CO INC | A | F |
| 218917 | 62607 | PHILIPS ELECTRONICS NORTH AMERIC | F | A |
| F48T12SW | 85271 | DURO-TEST CORP | A | F |
| 387001 | 77569 | NORTH AMERICAN PHILIPS CORP | A | C |
| F48T12SW | 08599 | ARC RAY ELECTRIC CORP | A | F |
| F48T12SW | 06RZ4 | DURO-TEST LIGHTING | F | A |
| F48T12SW | 08108 | LAMP INDUSTRY | A | M |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | X | A | 02/05/1 | Y | 9405400000 | 0389 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DA | Z | J2200X- | A | ||
| DS | N | I | |||
| DM | Z | 13B2B-- | M | ||
| GP | ------- | C | |||
| DN | 9B----U | N | |||
| DF | N | SF9SX-N | F |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | Y | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| GP | SMS | Z | Y | EA | 0 | U | ------- | C | |
| DN | SMS | Z | Y | EA | 0 | U | 9B----U | N | |
| DS | SMS | Z | Y | EA | 0 | U | D | ||
| DF | SMS | Z | 1 | EA | 0 | U | SF9SX-N | F | |
| DM | SMS | Z | Y | EA | 0 | U | Z | 13B2B-- | M |
| DA | SMS | Z | Y | EA | 0 | U | Z | J2200X- | A |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|---|---|---|---|
| J | 2 | 2 | 00 | X |
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 109600 | X | 55930 | J | 761 | Z | 9 | A | H | Z | LAMPS(BULBS) ELEC FLUORESCENT |