| AEAS |
MAJOR COMPONENTS |
ALTITUDE DELAY SIMULATOR; MONITOR UNIT; DELAY LINE; CABLE; CABLE-MONITOR ASSEMBLY; WAVEGUIDE HORN |
| AQXZ |
OPERATING TEST CAPABILITY |
ALTITUDE SIMULATION 150 FT AND 750 FT +/-2 PERCENT; ALTITUDE STEP FUNCTION MEASURED 10 +/- 0.1 SECOND; RADAR POWER MEASUREMENT 5 DB; LOOP SENSITITIVITY ABOVE 125 DB +/- 4 DB; INPUT POWER 108 V TO 121 V SINGLE PHASE, 380 CYCLES TO 420 CYCLES AND 21.5 VDC TO 29 VDC |
| FCLS |
FUNCTIONAL CLASSIFICATION |
AA-9.3 |
| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
OPERATING |
| ZZZV |
FSC APPLICATION DATA |
TEST SET RADAR, EXCEPT SPECIALLY DESIGNED |
| HGTH |
HEIGHT |
15.500 INCHES NOMINAL |
| ALSF |
INTERNAL BATTERY ACCOMMODATION |
NOT INCLUDED |
| ABGL |
WIDTH |
15.600 INCHES NOMINAL |
| ABRY |
LENGTH |
19.000 INCHES NOMINAL |
| ACYR |
DC VOLTAGE RATING |
21.5 VOLTS MINIMUM AND 29.0 VOLTS MAXIMUM |
| AQXY |
TEST TYPE FOR WHICH DESIGNED |
ALTITUDE RESPONSE, ALTITUDE TRACKING RATE,RF POWER MEASUREMENT |
| ANNQ |
MATERIAL AND LOCATION |
ALUMINUM HOUSING |
| RDAL |
REFERENCE DATA AND LITERATURE |
TO 1F-111A-4-18 & 33A1-12-411-4 |
| ANPZ |
INCLOSURE FEATURE |
MULTIPLE ITEM W/CARRYING CASE |
| ACZB |
FREQUENCY RATING |
380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM |
| ACYN |
AC VOLTAGE RATING |
108.0 VOLTS MINIMUM AND 121.0 VOLTS MAXIMUM |
| FAAZ |
PHASE |
SINGLE |