| ACZB |
FREQUENCY RATING |
60.0 MEGAHERTZ NOMINAL AND 50.0 MEGAHERTZ NOMINAL AND 400.0 MEGAHERTZ NOMINAL |
| ACYN |
AC VOLTAGE RATING |
115.0 VOLTS NOMINAL AND 230.0 VOLTS NOMINAL |
| RDAL |
REFERENCE DATA AND LITERATURE |
HP 1975 PRODUCT CATALOG |
| FEAT |
SPECIAL FEATURES |
OPT 004 IS HIGH PERFORMANCE CESIUM BEAM TUBE, AVG LIFE 10,000 HRS; ACCURACY:PORM 7 X 10E12 OVER TEMP 0-50 DEG C; STABILITY: PORM 3 X 10E12(1); SSB PHASE NOISE SIGNAL (1 HZ BW): -28 DB AT 10EM3 HZ/M140 DB AT 10E3; DC MAGNETIC FIELD STABILITY: PORM 2 X 10EM13, 2 GAUSS FIELD; FRONT AND REAR BNC; REPRODUCABILITY: PORM 3 X 10EM12(3); SETTABILITY: PORM 1 X 10EM13(3); AC MAGNETIC FIELD: LESS THAN 2 X 10EM12 FOR 2 GAUSS PEAK |
| AXGY |
MOUNTING METHOD |
BASE |
| BHZG |
INDIVIDUAL PLUG-IN UNIT FREQUENCY |
NOT RATED |
| AGAV |
END ITEM IDENTIFICATION |
OPERATION SYSTEMS AND NATIONAL LABORATORIES REFERENCE STANDARDS |
| BHZL |
RECORDING DEVICE ACCOMMODATION |
NOT PROVIDED |
| APQB |
UNIT TYPE |
STANDARD |
| AFGQ |
FREQUENCY RANGE RATING |
+0.100/+5.000 MEGAHERTZ |
| AWJN |
UNPACKAGED UNIT WEIGHT |
70.000 POUNDS |
| ABMK |
OVERALL WIDTH |
16.375 INCHES NOMINAL |
| ABHP |
OVERALL LENGTH |
16.750 INCHES NOMINAL |
| FTLD |
FUNCTIONAL DESCRIPTION |
PROVIDES PRECISE TIMING FOR FREQUENCY CONTROL BY PUTTING THE CORRECT FREQUENCY WITHIN VERY NARROW LIMITS |
| ABKW |
OVERALL HEIGHT |
8.750 INCHES NOMINAL |
| FAAZ |
PHASE |
SINGLE |