| ANPZ |
INCLOSURE FEATURE |
SINGLE ITEM W/HOUSING |
| FCLS |
FUNCTIONAL CLASSIFICATION |
AA-9.3 |
| ACYN |
AC VOLTAGE RATING |
115.0 VOLTS NOMINAL AND 230.0 VOLTS NOMINAL |
| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
OPERATING |
| ACZB |
FREQUENCY RATING |
47.0 HERTZ MINIMUM AND 450.0 HERTZ MAXIMUM |
| FEAT |
SPECIAL FEATURES |
INCLDES BATTERY BACKUP (10 TO 40 MINUTES); POWER 50 WATTS; 13 COMPATIBLE PLUG IN MODULES DO 40 FUNCTIONS; SELF CONTAINED PRINTER; REMOTE OPERATION MONITOR UNIT; 12 BUTTON KEYBOARD; CONTROLS: 3 SECTION KEYBOARD FOR PROGRAMMING AND CLOCK SET UP, FUNCTION KEYSWITCH, PRINTOUT MODE; HAS SELF CHECK OF MODULES AND COMPARISON TO STANDARDS; RS232C INTERFACE; THERMAL PRINTER USES 2.25 INCH BY 140 FT ROLL OF PAPER; OPERATING TEMP 10 TO 40 DEG C |
| AEJZ |
DEPTH |
15.500 INCHES NOMINAL |
| HGTH |
HEIGHT |
7.500 INCHES NOMINAL |
| AQXY |
TEST TYPE FOR WHICH DESIGNED |
VOLTAGE SURGES,SAGS,IMPULSES,BROWNOUTS,TEMPERATURE,HUMIDITY |
| SUPP |
SUPPLEMENTARY FEATURES |
MANUFACTURERS NAME: ANALYZER,DISTURBANCE |
| FTLD |
FUNCTIONAL DESCRIPTION |
ITEM IS DESIGNED TO ACCEPT MODULES FOR MEASURING A WIDE RANGE OF PARAMETERS AFFECTING THE OPERATION OF COMPUTERS, WORD PROCESSORS, TELEPHONE/TELECOMMUNICATIONS EQUIPMENT, AUTOMATED PRODUCTION SYSTEMS, MEDICAL INSTRUMENTS AND MILITARY AND AVIONICS SYSTEMS THAT ARE SENSITIVE TO FLUCTUATIONS IN AC AND DC POWER, TEMPERATURE, HUMIDITY AND OTHER ENVIRONMENTAL FACTORS |
| ABGL |
WIDTH |
11.000 INCHES NOMINAL |
| ALSF |
INTERNAL BATTERY ACCOMMODATION |
INCLUDED |