| ABKW |
OVERALL HEIGHT |
5.500 INCHES NOMINAL |
| ARYS |
INFORMATION RECORDED |
TRUE RMS CURRENT & VOLTAGE & PEAK CURRENT DATA FROM 6 INPUTS |
| ABHP |
OVERALL LENGTH |
13.500 INCHES NOMINAL |
| SUPP |
SUPPLEMENTARY FEATURES |
BATTERY PACK REQUIRES 4 "C" BATTERIES; A SWITCH SELECTS AC AND POWER; TRANSDUCERS, LEADS, AND JACKS ARE COLORCODED TO HELP PREVENT HOOK-UP ERRORS |
| ABMK |
OVERALL WIDTH |
10.000 INCHES NOMINAL |
| ACZB |
FREQUENCY RATING |
50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| ACYN |
AC VOLTAGE RATING |
120.0 VOLTS MINIMUM AND 440.0 VOLTS MAXIMUM |
| AGAV |
END ITEM IDENTIFICATION |
AN/TPS(V) SERIES RADAR SETS; NHA IS PRESSURE DEHYDRATOR |
| ALSF |
INTERNAL BATTERY ACCOMMODATION |
INCLUDED |
| ANBK |
RECORDING METHOD |
ANY ACCEPTABLE |
| FEAT |
SPECIAL FEATURES |
UNIT CAN DISPLAY 44 SEPARATE FUNCTIONS INCLUDING PRESENT PEAK, TIME OF PEAK, MINIMUM READINGS, TIME OF MINIMUM, MAXIMUM READINGS, TIME OF MAXIMUM, AVERAGE READINGS, SWEEP OF PRESENT READINGS, AND TOTAL TIME; THREE CLAMP ON CURRENT TRANSDUCERS MEASURE CIRCUITS UP TO 3-PHASE; AUTO-RANGING FINDS PROPER RANGE; COMPUTER RETAINS MEMORY IN CASE OF POWER LOSS; IN RECORD MODE THE UNIT MONITORS 9 READINGS WHILE SIMULTANEOUSLY IN SWEEP MODE; MEASURES TO 1000 VAC WITH ACCURACY PORM 1.5 PCT OF READING; TO 750 VAC WITH ACCURACY PORM 1.0 PCT OF READING |