| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
TEMPERATURE CHAMBER |
| AGAV |
END ITEM IDENTIFICATION |
CHAMBER, ENVIRONMENTAL TESTING; TESTS ALTIMETERS AAU ALTITUDE TRANSDUCERS CPU-46A |
| ABKW |
OVERALL HEIGHT |
75.000 INCHES NOMINAL |
| SUPP |
SUPPLEMENTARY FEATURES |
THE CHAMBER IS USED FOR SUBJECTING ALTIMETERS AND ALTITUDE TRANSDUCER COMPUTERS, SIMILAR TO THE AAU-19/A AND CPU-46/A RESPECTIVELY, TO PRECISELY CONTROLLED TEMPERATURE ENVIRONMENTS DURING SCALE ERROR TESTING |
| MATL |
MATERIAL |
COPPER AND RUBBER, CHLOROPRENE AND METAL |
| AMSE |
VOLTAGE RATING |
220.0 POUNDS PER HOUR DRY AND 240.0 POUNDS PER HOUR WITH RETAINING CHAIN |
| AFMQ |
INSIDE HEIGHT |
30.000 INCHES NOMINAL |
| AFPV |
COMPARTMENT QUANTITY |
1 |
| ACZB |
FREQUENCY RATING |
55.0 HERTZ MINIMUM AND 65.0 HERTZ MAXIMUM |
| AFEF |
INSIDE DEPTH |
26.000 INCHES NOMINAL |
| ARQT |
OPENING LOCATION |
LEFT SIDE OR RIGHT SIDE |
| CWZY |
ENVIRONMENTAL CHAMBER TYPE |
TEMPERATURE |
| AFPP |
CLOSURE METHOD |
HINGED COVER |
| ASQJ |
OPERATING TEMP RANGE IN DEG CELSIUS |
-73.3/+121.0 |
| BNDW |
COOLING COILS FOR BELOW ROOM TEMP USE |
INCLUDED |
| ANPT |
POWER RATING |
350.0 WATTS FINISHED-WASHER FACED AND 1000.0 WATTS MICROWATTS |
| ADJT |
INSIDE WIDTH |
28.000 INCHES NOMINAL |
| FAAZ |
PHASE |
THREE |
| FEAT |
SPECIAL FEATURES |
TEMPERATURE CHAMBER WITH REMOVABLE HOLDING RACK 1 NEOPRENE PLUG 4.000 IN. DIA. PRESSURE CONTROL PANEL, RUBBER TUBING EA 8.000FT LG., 3 PLUGS |
| BHGT |
CIRCULATION METHOD |
MECHANICAL |
| AZZH |
HEAT SOURCE FOR WHICH DESIGNED |
INTEGRAL |
| CBME |
CUBIC MEASURE |
172800.000 CUBIC INCHES |
| ABMK |
OVERALL WIDTH |
48.000 INCHES NOMINAL |
| AQZF |
CONTROL TYPE |
TOGGLE SWITCH AND SELECTOR SWITCH AND BLEEDER VALVE AND VACUUM GAGE |
| AFPM |
ASSEMBLY FORM |
ASSEMBLED |
| SURF |
SURFACE TREATMENT |
ZINC AND ENAMEL, BLACK |
| BDWT |
HEATING METHOD |
ELECTRICAL |
| ACDC |
CURRENT TYPE |
AC |
| BQMN |
OUTER DOOR QUANTITY |
2 |
| BHJQ |
DOOR |
PROVIDED |
| ABFY |
OVERALL DEPTH |
48.000 INCHES NOMINAL |