| AFMQ |
INSIDE HEIGHT |
19.000 INCHES NOMINAL |
| AFEF |
INSIDE DEPTH |
14.000 INCHES NOMINAL |
| BLST |
INSULATED CABINET |
PROVIDED |
| ADJT |
INSIDE WIDTH |
18.000 INCHES NOMINAL |
| BQMJ |
CABINET INNER WALL MATERIAL |
STEEL, CORROSION RESISTING |
| BQWH |
MATERIAL CHARACTERISTIC |
GRID |
| BQMT |
INNER DOOR MATERIAL |
STEEL |
| AQZF |
CONTROL TYPE |
THERMOSTAT |
| BPYK |
SHELF MATERIAL |
STEEL |
| BQMW |
INNER DOOR MOUNTING METHOD |
HINGE |
| BQMS |
INNER DOOR QUANTITY |
1 |
| BQMP |
OUTER DOOR MATERIAL |
STEEL |
| BHGT |
CIRCULATION METHOD |
MECHANICAL |
| AZZH |
HEAT SOURCE FOR WHICH DESIGNED |
INTEGRAL |
| BQWN |
VACUUM CHAMBER |
NOT INCLUDED |
| AMSE |
VOLTAGE RATING |
120.000 VOLTS NOMINAL |
| FEAT |
SPECIAL FEATURES |
SENSITIVITY +/- 0.25 DEG C; INCLUDES ADJUSTABLE NICKEL PLATED STEEL WIRE SHELVES; MAGNETIC DOOR CLOSURE; ADJUSTABLE AIR EXHAUST; EXTERIOR FINISHED IN BAKED SILICONE ENAMEL; INSULATED ON SIDES WITH 2.500 INCHES OF FIBERGLASS; SINGLE KNOB DUAL HYDRAULIC THERMOSTAT-ONE FOR CONTROL, ONE FOR AUTOMATIC SAFETY TO PREVENT TEMPERATURE OVERSHOOTING; RECOVERY TIME 18 MINUTES |
| BQMR |
OUTER DOOR INSULATION FEATURE |
INCLUDED |
| ANPT |
POWER RATING |
1460.0 WATTS NOMINAL |
| ACZB |
FREQUENCY RATING |
50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| BDWT |
HEATING METHOD |
ELECTRICAL |
| BQMH |
CABINET OUTER WALL MATERIAL |
STEEL |
| ASQJ |
OPERATING TEMP RANGE IN DEG CELSIUS |
+35.0/+215.0 |
| BGXH |
WATER JACKET |
NOT PROVIDED |
| ABFY |
OVERALL DEPTH |
18.000 INCHES NOMINAL |
| BQMN |
OUTER DOOR QUANTITY |
1 |
| ABKW |
OVERALL HEIGHT |
32.000 INCHES NOMINAL |
| ACDC |
CURRENT TYPE |
AC |
| BGZL |
SHELF QUANTITY |
6 |
| ABMK |
OVERALL WIDTH |
24.000 INCHES NOMINAL |
| FAAZ |
PHASE |
SINGLE |
| BGZM |
SHELF ADJUSTABILITY |
ADJUSTABLE |