6665-00-169-1447 ( D5-15-6527 )
NSN Information
NSN | FSC | NIIN | Item Name | INC |
---|---|---|---|---|
6665-00-169-1447 | 6665 | 001691447 | ALARM,CHEMICAL AGENT,AUTOMATIC | 2862 |
NSN Features
MRC | Parameter | Characteristics |
---|---|---|
ALPC | COMPONENT AND QUANTITY | OALARM UNIT,CHEMICAL AGENT AUTOMATIC ALARM,M42 /FSN6665-859-2215/,1,BATTERY,DRY /BA3517/,/FSN6135-450-3528/,1,BATTERY,DRY /BA3202/,/FSN6135-935-8738/,4,DETECTOR UNIT,CHEMICAL AGENT AUTOMATIC ALARM M43 /FSN6665-859-2201/,1,INSTALLATION KIT,CHEMICAL AGENT AUTOMATIC ALARM /FOR TRUCK,UTILITY,1/4 TON/ /FSN6665-479-2716/,1,MOUNTING KIT,CHEMICAL AGENT AUTOMATIC ALARM,M228 /HIGH PROFILE/ /FSN6665-859-2212/,1,REFILL KIT,CHEMICAL AGENT AUTOMATIC ALARM,M229 /FSN6665-859-2214/,1 |
APGF | DESIGN TYPE | NONTRIPOD MOUNTING |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
AMKD | INDICATOR TYPE | FLASHING RED LIGHT AND HORN |
ALBY | USAGE DESIGN | FIELD |
ALXZ | SPECIFIC USAGE DESIGN | SAMPLES AIR CONTINUOUSLY,WHICH IS AUTOMATICALLY HEATED /IF NECESSARY/,FILTERED,DRAWN INTO THE DETECTOR CELL WHERE IT PASSES THROUGH THE ELECTROLYTE SOLUTION. IF V OR G AGENT ARE PRESENT,THE GALVANIC VOLTAGE PRODUCED BY THE CELL INCREASES. THE CHANGE IS AMPLIFIED BY THE ELECTRONIC MODULE WHICH SOUNDS THE DETECTOR HORN AND/OR ACTIVATES A FLASHING LIGHT,APPLIES POWER TO THE REMOTE TERMINALS AND STOPS THE PUMP MOTOR,THE HORN WILL CONTINUE TO SOUND AND/OR THE LIGHT FLASH UNTIL THE DETECTOR IS RESET OR DISCONNECTED BY THE OPERATOR. THE SYSTEM IS DESIGNED FOR MANPACK AND VEHICULAR APPLICATION USING DRY CELL BATTERY FOR MANPACK AND MOUNTING KIT AND INSTALLATION KIT FOR 1/4 TON UTILITY TRUCK APPL |
ACYR | DC VOLTAGE RATING | 28.0 VOLTS NOMINAL |
FEAT | SPECIAL FEATURES | ALSO DETECTS V CHEMICAL AGENT ANDCAN BE USED ON VEHICLES |
BRQN | MEDIA DETECTED | G CHEMICAL AGENT |
Manufacturing Part Numbers (SKUs)
Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
---|---|---|---|---|---|---|---|
D5-15-6527 | 81361 | A | 2 | 3 | 1 | BF |
Manufacturers
Part SKU | Cage | Manufacturer | Type | Status |
---|---|---|---|---|
D5-15-6527 | 81361 | EDGEWOOD CHEMICAL BIOLOGICAL CEN | A | A |
FLIS Identification
PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
---|---|---|---|---|---|---|---|---|---|---|
U | X | C | 1 | 12/23/1 | P | 9027505000 | 2862 |
FLIS Management
MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
---|
Demilitarization Codes & Management
DML | PMI | HMIC | ADP | CC | ESDC |
---|
Miscellaneous Management
MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
---|
Management Control Army
MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
---|
Freight
NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
---|---|---|---|---|---|---|---|---|---|---|---|---|
061700 | X | 34580 | J | M | 658 | Z | 9 | A | H | Z | ELEC APPLIANCES/INSTRUMENTS NOI |