| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
DETECTOR/MONITOR, HYDRAZINE |
| RDAL |
REFERENCE DATA AND LITERATURE |
CID A-A-59707 |
| APGF |
DESIGN TYPE |
NONTRIPOD MOUNTING |
| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
OPERATING |
| AWJN |
UNPACKAGED UNIT WEIGHT |
40.000 POUNDS |
| AMKD |
INDICATOR TYPE |
HORN |
| ALXZ |
SPECIFIC USAGE DESIGN |
MONITOR LEVEL OF H-70 (70% HYDRAZINE, 30% WATER) VAPORS, AND SOUND ALARM IF IT REACHES HAZARDOUS LEVELS |
| BRQN |
MEDIA DETECTED |
EXPLOSIVE GAS AND COMBUSTIBLE GAS AND VOLATILE VAPOR |
| AFJK |
CUBIC MEASURE |
4000.000 CUBIC INCHES |
| ACZB |
FREQUENCY RATING |
50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| ALBY |
USAGE DESIGN |
INDUSTRIAL AND FIELD AND DOMESTIC AND SHIPBOARD |
| ACYN |
AC VOLTAGE RATING |
105.0 VOLTS MINIMUM AND 240.0 VOLTS MAXIMUM |
| FAAZ |
PHASE |
SINGLE |
| FTLD |
FUNCTIONAL DESCRIPTION |
CONTINOUSLY DETECTS/MONITORS TOXIC AMOUNTS OF HYDRAZINE VAPORS IN OPEN & ENCLOSED AREAS. INTENDED FOR BENCH TOP USE TO MONITOR THE LEVEL OF HYDRAZINE PRESENT IN WORKING ENVIRONMENTS WHEN SERVICING, MAINTAINING, & OVERHAULING AIRCRAFT COMPONENTS & ASSEMBLIES IN AN IMMEDIATE WORK AREA WHERE EXPOSURE TO HYDRAZINE VAPORS EXIST |