| SUPP |
SUPPLEMENTARY FEATURES |
SENSOR NOT SUITED FOR USE IN CHEMICALS, SOLVENTS, OR PETROLEUM, IN HIGH VAPOR-PRESSURE MATERIALS, OR UNDER CRYOGENIC OR HIGH-LEVEL NUCLEAR RADIATION CONDITIONS; TEMPERATURE RANGE 5 TO 158 DEG F; WETTED MATERIALS MYLAR, ACRYLIC AND GLASS-FILLED POLYPROPYLENE, SLIP NUT CHROME PLATED BRASS; ACTIVE HELIX STARTS 12 IN FROM SENSOR ZERO, EXTENDS TO APPROX 1.6 IN FROM SENSOR BOTTOM; HELIX RESOLUTION ONE QUARTER INCH; ACTUATION DEPTH NOMINAL 5 INCH HEAD OF WATER, OFFSET AT CALIBRATION; SENSOR WEIGHT 5.5 LB PLUS .15 LB/FT |
| ABHP |
OVERALL LENGTH |
18.35 MILLIMETERS NOMINAL |
| AGAV |
END ITEM IDENTIFICATION |
TANK LEVEL & DRAFT GAUGING SYSTEM |
| FTLD |
FUNCTIONAL DESCRIPTION |
USED FOR WATER APPLICATIONS, INCLUDING FRESH AND SALT WATER, MUNICIPAL WASTEWATER, SEWAGE, AND WATER-BASED SLURRIES AND SUSPENSIONS WITH TEMPERATURES UP TO 158 DEG F |
| MATL |
MATERIAL |
PLASTIC, THERMOPLASTIC |
| FEAT |
SPECIAL FEATURES |
6ALL ELECTRIC RESISTANCE-TAPE SENSOR FOR STABLE OUTPUT, NO MOVING PARTS TO STICK OR BREAK; TANK TOP MOUNTED FOR EASY INSTALLATION; 5 MINUTE FILTER CHANGE EVERY 24 TO 48 MONTHS; COMBINED LEVEL AND TEMPERATURE CAPABILITY; HIGH RESOLUTION RESISTANCE HELIX AND GOLD-ON-GOLD ELECTRIC CONTACTS FOR ONE QUARTER TURNS RESOLUTION AND LONG TERM CONTACT STABILITY; THE SENSOR JACKET IS MULTI-LAYER, PRINCIPALLY MYLAR POLYESTER AND PROTECTED ON THREE SIDES WITH AN EXTRUDED GLASS-FILLED POLYPROPYLENE BUMPER CHANNEL |
| ZZZV |
FSC APPLICATION DATA |
NHA PN 7100003-019M |