| AWTN |
OPERATING TEMP RATING |
140.0 DEG FAHRENHEIT MAXIMUM |
| ADAV |
OVERALL DIAMETER |
3.380 INCHES NOMINAL |
| ABHP |
OVERALL LENGTH |
244.250 INCHES NOMINAL |
| ACYN |
AC VOLTAGE RATING |
120.0 VOLTS NOMINAL |
| BJKH |
LIQUID TYPE FOR WHICH DESIGNED |
NON-POTABLE WATER AND SEWAGE |
| ALSF |
INTERNAL BATTERY ACCOMMODATION |
NOT INCLUDED |
| BJKC |
MAXIMUM CURRENT RATING |
55.0 AMPERES NOMINAL LOAD |
| AXGY |
MOUNTING METHOD |
CLAMP |
| AGBD |
ELECTRICAL CONNECTION TYPE |
CABLE AND CONNECTOR PLUG |
| APGW |
CURRENT RATING AT MAXIMUM RATED VOLTAGE |
15.0 AMPERES NOMINAL LOAD |
| ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL |
| AFLW |
ACTUATION METHOD |
BUOYANCY |
| CWTL |
FLOAT AND CONTACT POSITIONS |
FLOAT DOWN, CONTACTS OPEN |
| APGY |
VOLTAGE RATING AT MAXIMUM RATED CURRENT |
120.0 VOLTS |
| FEAT |
SPECIAL FEATURES |
PUMPING RANGE 6.5 TO 13.5 INCHES, HAS 20FT WATER RESISTANT CABLE, HIGH IMPACT; CORROSION RESISTANT; PVC HOUSING FOR MERCURY SWITCH HERMETICALLY SEALED IN STEEL CAPSULE, SWITCH MUST BE USED WITH PUMPS PROVIDING INTEGRAL THERMAL OVERLOAD |
| AWAE |
FLOAT QUANTITY |
1 |
| AGAV |
END ITEM IDENTIFICATION |
BEAR WATER SYSTEM |
| FAAZ |
PHASE |
SINGLE |