| CKRD |
SENSING ELEMENT TYPE AND LOCATION |
THERMOCOUPLE REMOTE |
| ATJK |
POWER SOURCE |
EXTERNAL |
| ASXT |
OPERATING RANGE |
0 TO 400 DEG F, 0 TO 200 DEG C |
| NTRD |
ENTRY DATE |
80-10-21 |
| RTSE |
RELATIONSHIP TO SIMILAR EQUIPMENT |
6685-00-766-0237 |
| CHQQ |
MAXIMUM OVERALL WIDTH |
18.000 INCHES |
| FTLD |
FUNCTIONAL DESCRIPTION |
DESIGNED TO CONTROL HEATING BLANKETS DURING AIRCRAFT HONEYCOMB REPAIR |
| FCLS |
FUNCTIONAL CLASSIFICATION |
JJ-6 |
| AFXE |
MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC |
| CHQP |
MAXIMUM OVERALL LENGTH |
14.000 INCHES |
| RDAL |
REFERENCE DATA AND LITERATURE |
T.O. 33A29-2-2-1 |
| FEAT |
SPECIAL FEATURES |
UPPER PART OF THE CASE CONTAINS THE POWER CABLE ASSEMBLY, THERMOCOUPLES, AND THERMOCOUPLE EXTENSION CABLE; LOWER SECTION OF CASE HAS THE CONTROL UNIT INSTRUMENT PANEL, RELAY AMPLIFIER ASSEMBLY, RELAY PANEL AND MEASURING CIRCUIT PANEL; ITEM IS PORTABLE; PYROMETER INDICATES TEMP IN FARENHEIT AND CENTIGRADE; CONTROL THERMOCOUPLE SAFETY FEATURE LIMITS THE TEMP NOT TO EXCEED 375 DEG F (190 DEG C); WEIGHT 30 LBS |
| AGAV |
END ITEM IDENTIFICATION |
STRUCTURAL REPAIR KIT |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
TEMPERATURE CONTROL SET |
| FAAZ |
PHASE |
SINGLE |
| CHQR |
MAXIMUM OVERALL HEIGHT |
8.000 INCHES |
| FREQ |
FREQUENCY IN HERTZ |
400.0 |